The learner will demonstrate knowledge of quality control and inspection for GMAW.

GMAW: Inspection & Quality Control Set 2

Inadequate welding current causes ________________.

Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Correct!

Inadequate welding current causes ________________.

Correct Answer

incomplete joint penetration

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Incorrect

Inadequate welding current causes ________________.

Your Answer

Correct Answer

incomplete joint penetration

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Excessive contact tube-to-work distance causes ________________.

Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Correct!

Excessive contact tube-to-work distance causes ________________.

Correct Answer

porosity

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Incorrect

Excessive contact tube-to-work distance causes ________________.

Your Answer

Correct Answer

porosity

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Inadequate shielding gas coverage causes _______________.

Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Correct!

Inadequate shielding gas coverage causes _______________.

Correct Answer

porosity

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Incorrect

Inadequate shielding gas coverage causes _______________.

Your Answer

Correct Answer

porosity

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Correct!

What are the causes of difficult arc starting and erratic arc?

Correct Answer

Wrong polarity

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Incorrect

What are the causes of difficult arc starting and erratic arc?

Your Answer

Correct Answer

Wrong polarity

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

What causes the electrode wire to feed but not to be energized?

Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Correct!

What causes the electrode wire to feed but not to be energized?

Correct Answer

No workpiece connection

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Incorrect

What causes the electrode wire to feed but not to be energized?

Your Answer

Correct Answer

No workpiece connection

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Correct!

What are the causes of irregular wire feed and burn back?

Correct Answer

Contact tube plugged or worn

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Incorrect

What are the causes of irregular wire feed and burn back?

Your Answer

Correct Answer

Contact tube plugged or worn

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Correct!

What causes the wire to feed but no shielding gas to flow?

Correct Answer

Gas cylinder valve closed

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Incorrect

What causes the wire to feed but no shielding gas to flow?

Your Answer

Correct Answer

Gas cylinder valve closed

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Correct!

What causes porosity in the weld bead?

Correct Answer

Gas cylinder valve closed

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Incorrect

What causes porosity in the weld bead?

Your Answer

Correct Answer

Gas cylinder valve closed

 Next Question
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Correct!

What causes the wire feed motor to operate but the wire not to feed through?

Correct Answer

Insufficient drive roll pressure

 Finish
Question 1 of 10

GMAW: Inspection & Quality Control Set 2

Incorrect

What causes the wire feed motor to operate but the wire not to feed through?

Your Answer

Correct Answer

Insufficient drive roll pressure

 Finish
Question 1 of 10
GMAW: Inspection & Quality Control Set 2

Score

You have answered 5 of 10 questions correctly.

50%

Start Over

See other flashcards and apps related to:

Question 1 of 10
Author
Published
Last Updated
7/30/2015
Tags

No Comments Yet

Creative Commons License
GMAW: Inspection & Quality Control Set 2 by Fox Valley Technical College is licensed under a Creative Commons Attribution 3.0 Unported License.